background image

Jaguar Model J-390

2

WELCOME TO OUR VALUED CUSTOMER

You are now the owner of a Slant/Fin Jaguar gas-fired boiler,

another quality heating product designed and manufactured

by an industry leader, to provide your family with many years

of reliable comfort and trouble-free performance.

The care and maintenance of your new boiler is important to

prevent a hazardous condition which might result form lack

of proper servicing. Therefore, you should perform regular

“owner” inspections as described in this manual (and report

any concerns to a qualified service technician) as well as

have your boiler serviced by a qualified service technician at

least once a year, preferably before the beginning of each

heating season.

LIGHTING INSTRUCTIONS

Locate, read and then follow the procedures on the lighting

instructions label attached to the boiler. For reference, we

have reproduced those instructions in this manual. 

DO NOT use this boiler if any part has

been underwater. Immediately call a

qualified service technician to inspect the

boiler and to replace any part of the control

system and any gas control which has

been underwater. 

WARNING

Should overheating occur or the gas

supply fail to shut off, DO NOT turn off or

disconnect the electric supply to the

circulator pump. Instead, shut off the gas

supply at a location EXTERNAL to the

appliance. 

WARNING

SLANT/FIN DOES NOT PERMIT THE USE

OF VENT DAMPERS ON JAGUAR

BOILERS. OTHER DAMPERS OR DEVICES

WITH SIMILAR PURPOSE ARE NOT 

PERMITTED.

Keep the boiler area clean and free of all materials that can burn. 

NEVER close or reduce openings that supply air 

for the boiler fire and for ventilation. 

Figure 1. Location and identification of parts.

SPARK ELECTRODE

(IGNITER)

HEAT EXCHANGER

VENTURI

WINDOW

(SIGHT GLASS)

FLUE PIPE

FLUE SENSOR

GAS SUPPLY

VALVE

WATER SUPPLY

WATER RETURN

CONDENSATE

TRAP

WATER RETURN

SENSOR

WATER SUPPLY SENSOR AND

WATER HIGH LIMIT

CONDENSATE

TRAP

FRONT (INTERIOR)

RIGHT SIDE (INTERIOR)

PRESSURE GAUGE

POWER SWITCH

TEMPERATURE DISPLAY

MODE DISPLAY

VENT

AIR INTAKE

PRESSURE

RELIEF VALVE

Summary of Contents for J-390

Page 1: ...nity of this or any other appliance __ WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas suppli er s instructions If you cannot reach your gas supplier call the fire department __ Installation and service must be performed by a qualified ins...

Page 2: ...s boiler if any part has been underwater Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been underwater WARNING Should overheating occur or the gas supply fail to shut off DO NOT turn off or disconnect the electric supply to the circulator pump Instead shut off the gas supply at a location EXTERNAL t...

Page 3: ... Non direct vent installation is shown on Figures 4 5 and 6 1 VENTING AND AIR INTAKE SYSTEM REGULAR INSPECTION Inspect the system regularly for condensation corrosion sagging and or physical damage A qualified professional should service the boiler annually and include such an inspection at that time The homeowner should look over the system monthly for damage water stains any signs of rust other ...

Page 4: ...Jaguar Model J 390 4 AIR INTAKE DO NOT BLOCK 4 DIA VENT PIPE VENT TERMINATION OUTSIDE WALL Figure 4 Non direct vent sidewall venting 102mm 4 DIA VENT PIPE ...

Page 5: ...RMINATION 4 DIA VENT PIPE AIR INTAKE DO NOT BLOCK Figure 6 Non direct vent utilizing an existing chimney as a chase VENT TERMINATION CHIMNEY TOP PLATE 4 DIA VENT PIPE 4 DIA VENT PIPE AIR INTAKE DO NOT BLOCK UNUSED CHIMNEY 102mm 4 DIA VENT PIPE 102mm 4 DIA VENT PIPE 102mm 4 DIA VENT PIPE ...

Page 6: ...ure is normally indicated on the tempera ture display See Figure 1 for location and Figure 9 for digits illustration For most installations it should indicate about 83 to 103 kPa 12 to 15 psi pressure when temperature is about 21 to 38 C 70 to 100 F and from 103 to 172 kPa 15 psi to 25 psi when tem perature is up to 91 C 195 F FOR YOUR SYSTEM there is one correct pressure for each temperature ASK ...

Page 7: ...uilding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to turn the gas supply shut off valve Never use tools If the supply shut off will not turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or ex...

Page 8: ... C 90 to 185 F 2 While d is blinking boiler supply water tempera ture for DHW may be set to desired temperature The setting range is between 40 to 85 C 104 to 185 F 3 While t is blinking DHW tank temperature may be set to desired temperature if tank is equipped with sensor The setting range is between 40 to 85 C 104 to 185 F 4 View actual following temperatures on Temperature Display Press Select ...

Page 9: ...pressed to resume normal operation Error Condition Temperature display indicates the error code Warning Condition Temperature display indicates the error code Jaguar Boiler Display Board Boiler Operation Status Note Blinking dot on Mode Display indicates active heating control burner off Steady dot indicates burner is on Error must be corrected to resume boiler operation Pressing the Reset button ...

Page 10: ...Settable from 40 to 71 C 104 F to 160 F steps of 0 55 C 1 F The default valve is 60 C 140 F Press Enter button to store see note 3 Temperature display shows actual supply water temperature Temperature display shows actual return water temperature Temperature display shows actual DHW tank temperature if the water tank is equipped with sensor Temperature display shows actual flue gas temperature Tem...

Page 11: ...d once the condition returns to normal or is fixed The temperature display shows the error code Pressing the Reset button is not required C WARNING ERRORS Indicated by an H in the mode display Operation of the space heating mode is not affected and the warning is displayed intermittently Operation of the DHW mode is automatically restored once the condition is fixed The temperature display shows t...

Page 12: ... FIN LTD LTEE 6450 Northam Drive Mississauga Ontario L4V 1H9 Phone 905 677 8400 FAX 905 677 1829 Order Desk Fax 905 677 9015 www slantfin ca E mail orderdesk slantfin ca info slantfin ca Slant Fin Corp 2008 ...