Jaguar Model J-390

3

INSPECTION

Your boiler and heating system will last an indefinitely long

time at full efficiency, if it is inspected regularly and is kept

in good repair and adjustment. You, the user, should make

regular inspections, and report any problems to your ser-

vice agency. At regular intervals, you should have that

agency inspect the system and make repair adjustments

as necessary. What you and the service agency should do

is listed below. Contact your gas supplier for a list of qual-

ified service and repair agencies. 

USER INSPECTION

The user should make the following inspections at least

once each month during the heating season and once

just before cold weather starts. Jaguar J-390 boiler may

be installed and vented either as direct-vent boiler, which

all air for combustion is obtained directly from outside

through the air intake piping or as non-direct-vent boiler,

which all air for combustion is taken from inside the boiler

room. Typical direct-vent installations are shown on

Figures 2 and 3. Non-direct-vent installation is shown on

Figures 4, 5 and 6.

1. VENTING AND AIR INTAKE SYSTEM REGULAR

INSPECTION

Inspect the system regularly for condensation, corrosion,

sagging and/or physical damage. A qualified professional

should service the boiler annually and include such an

inspection at that time. The homeowner should look over

the system monthly for damage, water stains, any signs of

rust, other corrosions or separation of the vent and air

intake piping (if direct-vent).

Should an inspection turn up signs of condensation, corro-

sion, sagging or damage, the boiler should be shut down

immediately and the condition should be corrected by a

qualified professional.

If the boiler is vented horizontally through the wall, the out-

side termination, louvers and screen should be checked for

any debris blocking the opening and cleaned as required. 

OUTSIDE

TERMINATION

PANEL

AIR INTAKE

LOUVERS

OUTSIDE WALL

4" DIA

AIR INTAKE

4" DIA

VENT PIPE

VENT

TERMINATION

Figure 2. Direct vent, sidewall venting illustration.

4" DIA

VENT PIPE

4" DIA AIR

INTAKE PIPE

AIR INTAKE

VENT TERMINATION

Figure 3. Direct vent, venting and air intake
through a roof.

102mm (4") DIA.

AIR INTAKE

102mm (4")

DIA.

AIR INTAKE

102mm (4") DIA.

VENT PIPE

102mm

(4") DIA.

VENT

PIPE

Summary of Contents for J-390

Page 1: ...nity of this or any other appliance __ WHAT TO DO IF YOU SMELL GAS DO NOT try to light any appliance DO NOT touch any electrical switch DO NOT use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas suppli er s instructions If you cannot reach your gas supplier call the fire department __ Installation and service must be performed by a qualified ins...

Page 2: ...s boiler if any part has been underwater Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control which has been underwater WARNING Should overheating occur or the gas supply fail to shut off DO NOT turn off or disconnect the electric supply to the circulator pump Instead shut off the gas supply at a location EXTERNAL t...

Page 3: ... Non direct vent installation is shown on Figures 4 5 and 6 1 VENTING AND AIR INTAKE SYSTEM REGULAR INSPECTION Inspect the system regularly for condensation corrosion sagging and or physical damage A qualified professional should service the boiler annually and include such an inspection at that time The homeowner should look over the system monthly for damage water stains any signs of rust other ...

Page 4: ...Jaguar Model J 390 4 AIR INTAKE DO NOT BLOCK 4 DIA VENT PIPE VENT TERMINATION OUTSIDE WALL Figure 4 Non direct vent sidewall venting 102mm 4 DIA VENT PIPE ...

Page 5: ...RMINATION 4 DIA VENT PIPE AIR INTAKE DO NOT BLOCK Figure 6 Non direct vent utilizing an existing chimney as a chase VENT TERMINATION CHIMNEY TOP PLATE 4 DIA VENT PIPE 4 DIA VENT PIPE AIR INTAKE DO NOT BLOCK UNUSED CHIMNEY 102mm 4 DIA VENT PIPE 102mm 4 DIA VENT PIPE 102mm 4 DIA VENT PIPE ...

Page 6: ...ure is normally indicated on the tempera ture display See Figure 1 for location and Figure 9 for digits illustration For most installations it should indicate about 83 to 103 kPa 12 to 15 psi pressure when temperature is about 21 to 38 C 70 to 100 F and from 103 to 172 kPa 15 psi to 25 psi when tem perature is up to 91 C 195 F FOR YOUR SYSTEM there is one correct pressure for each temperature ASK ...

Page 7: ...uilding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to turn the gas supply shut off valve Never use tools If the supply shut off will not turn by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or ex...

Page 8: ... C 90 to 185 F 2 While d is blinking boiler supply water tempera ture for DHW may be set to desired temperature The setting range is between 40 to 85 C 104 to 185 F 3 While t is blinking DHW tank temperature may be set to desired temperature if tank is equipped with sensor The setting range is between 40 to 85 C 104 to 185 F 4 View actual following temperatures on Temperature Display Press Select ...

Page 9: ...pressed to resume normal operation Error Condition Temperature display indicates the error code Warning Condition Temperature display indicates the error code Jaguar Boiler Display Board Boiler Operation Status Note Blinking dot on Mode Display indicates active heating control burner off Steady dot indicates burner is on Error must be corrected to resume boiler operation Pressing the Reset button ...

Page 10: ...Settable from 40 to 71 C 104 F to 160 F steps of 0 55 C 1 F The default valve is 60 C 140 F Press Enter button to store see note 3 Temperature display shows actual supply water temperature Temperature display shows actual return water temperature Temperature display shows actual DHW tank temperature if the water tank is equipped with sensor Temperature display shows actual flue gas temperature Tem...

Page 11: ...d once the condition returns to normal or is fixed The temperature display shows the error code Pressing the Reset button is not required C WARNING ERRORS Indicated by an H in the mode display Operation of the space heating mode is not affected and the warning is displayed intermittently Operation of the DHW mode is automatically restored once the condition is fixed The temperature display shows t...

Page 12: ... FIN LTD LTEE 6450 Northam Drive Mississauga Ontario L4V 1H9 Phone 905 677 8400 FAX 905 677 1829 Order Desk Fax 905 677 9015 www slantfin ca E mail orderdesk slantfin ca info slantfin ca Slant Fin Corp 2008 ...

Reviews: