3.3
Engine Related Emergencies
3.3.1
Engine Failure During Take-off
1.
Throttle ......................................... IDLE
2.
Brakes ............................................ APPLY
with aircraft under control –
3.
Ignition Lanes / Magnetos ............. OFF
(BOTH)
4.
Master ........................................... OFF
5.
Fuel Selector .................................. OFF
6.
Fuel Pump(s) ................................. OFF
(BOTH)
3.3.2
Engine Failure Immediately After Take-Off
1.
Airspeed ........................................ 72 KIAS
2.
Landing Area ................................. LOCATE
(CLEAR GROUND)
3.
Flaps .............................................. AS NEEDED
4.
Fuel Pump(s) ................................. OFF
(BOTH)
5.
Fuel Selector .................................. OFF
before touch-down –
6.
Ignition Lanes / Magnetos ............. OFF
(BOTH)
7.
Master ........................................... OFF
WARNING
Flaps and elevator trim will not operate with the master switch off,
and they are powered by the main bus. Make final flap and trim
selection before turning master switch off.