background image

LIMITED WARRANTY

Unless otherwise noted, Sloan Valve Company warrants its products, manufactured and sold for commercial or industrial uses, to be free from defects of material and workmanship for a 

period of three (3) years (one year for SF faucets, special finish and PWT electronics and 30 days on PWT software) from the date of first purchase. During this period, Sloan Valve Company 

will, at its option, repair, replace, or refund the purchase price of any produce which fails to conform with this warranty under normal use and service. This shall be the sole and exclusive 

remedy under this warranty. Products must be returned to Sloan Valve Company, at customer’s cost. No claims will be  be allowed for labor, transportation or other costs. This warranty 

extends only to persons or organizations that purchase Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. 

THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY RESPONSIBLE FOR ANY 

CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.

MCR 4014, MCR 8012 CONTROLLERS 

INSTALLATION AND PROGRAMING INSTRUCTIONS

PRIOR TO INSTALLATION

Before you install the MCR series controller, be sure the items listed below are installed. 

• 24 VAC step down transformer • Push buttons • Flushometer • Lavatory/Shower solenoids

IMPORTANT

• ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS.

• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.

• FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS.

• ALL ELECTRICAL WIRING IS TO BE INSTALLED IN ACCORDANCE WITH NATIONAL/LOCAL CODES AND REGULATIONS.

 

Installation of the PWT MICROPlumb

®

 MCR 4014, MCR 8012 and MCR-8013 Series Controller incorporates the latest advances in microprocessor technology to provide maximum control of your plumbing 

system. MICROPlumb

®

 patented sensing and metering products can be programmed to do just about anything you require, when you require it, including the ability to Delay and Lock-Out fixture activation. 

MICROPlumb products control showers, water closets, lavatories and combination fixtures and help maintain operation of ON/OFF/DELAY. These modular, flexible systems for new constructions, retrofit or 
expansion applications have few moving parts, no mechanical metering devices, and operate on low voltage to ensure safety and reliability. The following instructions will serve as a guide when installing the MCR 
4000 and MCR 8000 Series Controllers. As always, good safety practices and care are recommended when installing your new controller.

MCR 4014, MCR 8012 CONTROLLERS

INSTALLATION AND PROGRAMING 

INSTRUCTIONS

CODE NO. 0816865 
Rev.1 (08/19)

1

Prior to Installation

Summary of Contents for PWT MCR 4014

Page 1: ...4 VAC step down transformer Push buttons Flushometer Lavatory Shower solenoids IMPORTANT ALL PLUMBING SHOULD BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES AND REGULATIONS WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN ADEQUATE VOLUME OF WATER FOR EACH FIXTURE FLUSH ALL WATER LINES PRIOR TO MAKING CONNECTIONS ALL ELECTRICAL WIRING IS TO BE INSTALLED IN ACCORDANCE WITH NATIONAL LOCAL CODES AND RE...

Page 2: ...lluminate 4 Turn power off until pushbuttons and solenoids are installed IMPORTANT Be sure that wire is completely inserted into terminal and that no strands are crossing from one side to the other 1 Confirm power is off 2 Plug RJ 11 connectors from push buttons into appropriate input connections in controller Refer to Operating Chart sheet for input output designations 3 Plug RJ 11 connectors fro...

Page 3: ...e number of times that LED 18 flashes Each flash relates to a time increment that increases either a runtime or lockout time When adjusting runtime each flash equals 30 seconds When adjusting a lockout each flash equals 15 minutes 5 Repeat steps 2 4 until LED flashes for appropriate timing 5 Close Polycarbonite Cover and Remove 1 Close the polycarbonate cover 2 Tighten two cover screws Application...

Page 4: ...ot flush CAUSE No water is being supplied to valve SOLUTION Make sure the water supply is turned on at the control stop Check to see if any ball or gate valves have been turned off up stream of the control stop CAUSE The EL 163 A Solenoid shaft assembly is fouled or jammed SOLUTION Turn the power off to the valve Failure to do so could result in damage to the solenoid coil Remove the EL 166 nut fr...