Occupancy Indicator Light Installation
Cutout template
(shown to scale)
Ø .375" (10 mm)
2.375"
(60 mm)
3.5625"
(91 mm)
1.
Tools required:
Wire strippers, drill, tape
measure, screwdriver, and drywall saw.
2.
Wireless receiver and indicator light
location:
Locate switch inside restroom.
Measure height to top of outlet box.
3. On opposite side of wall (outside of restroom),
measure 3" (76 mm) above height of switch
and make cutout for indicator light as shown
in "Cutout Template" shown below.
H
H+3"
(76 mm)
Inside restroom
Outside restroom
4.
Receiver mounting:
Wireless receiver
mounts to electrical box using threaded
connector as shown.
External sensor in
12V DC out
0-10V- (Gray)
0-10V+ (Purple)
Relay load (Red)
Ho
t, 1
20
-2
77 V
AC (
Bl
ac
k)
Ne
ut
ra
l (
W
hi
te
)
Orange, Gray,
and Purple wires:
Connect to indicator
light connector
Yellow wire
capped, not used
Red wire capped,
not used
5.
AC voltage wiring:
Connect line voltage to
BLACK wire and neutral to WHITE wire. RED
and YELLOW wires are not used.
Touchless Occupancy Indicator System
Installation Guide for 601146, 601147, 601148, and 601153
PAGE 1 OF 3