Ref : 26702 25 07/01/15
FAIL SOFT OPERATION
If the card detects an encoder problem (Err6) and to not stop the device, it
continues to operate in fail soft mode.
It consists of executing the open and close cycles at slow speed without
shock detection during the door opening or closing operations.
Limit switches are given by a rather long timeout in order to cover the
cycle time of the largest doors.
During these movements, if it is parameterized, the Buzzer output is
activated.
OPERATION WITH CAR DOOR LOCKING DEVICE
When the operator is equipped with a Car Door Locking device (VPC) which
is triggered by the start of an open travel in front of a landing door, it is
necessary to increase the skate open travel (CS-O) by the value of the VPC
unlocking travel so that it is opened in slow speed before the acceleration
of the door panels to avoid making noise.
ENERGY SAVE OPERATION
Motor consumption energy save :
For the sake of saving energy and reducing equipment wear, it is possible
to allow the ARIANE card to go into reduced opening and closing speeds if
calls are spaced far apart.
The wait time between calls is adjusted by
TA-O
and the desired cruise
speed reduction by
R-FP
TA-O
Wait time before going into energy save mode (adjustment
range : 15 to 90 minutes).
R-FP
Frequency reduction ratio 0 to 50% of the cruise speeds in
energy save mode.
(r-FP = 0 de-activates the energy save mode)
Display screen saver :
If after a few minutes the card keyboard is not activated, the display
switches off and only a point moves on it.