Ref : 26702 31 07/01/15
To return to the parameter list, press
.
T
EST
S AND ADJUST
E
M
E
NT
T
O
DO
Reprogram card parameters following paragraph with title
« On-site replacement of
an ARIANE card » page 21
Erase memory following indications page 37 and check if
faulty operation appears again.
Check U1. and U2. Voltage parameters and decrease them.
Check winding, wiring (court-circuit)
Check U1. and U2. Voltage parameters and decrease them.
Check winding, wiring (court-circuit)
Check U1. and U2. Voltage parameters and decrease them.
See problems met : "the door doesn’t see the encoder
anymore”
Check the 3 windings balance.
Check the m
otor’s wiring.
Ramener la tension secteur à 220 V thanks to a
transformateur
Increase deceleration times
Reduce mains power voltage to 220 V à l'aide d'un
transformer
Erase memory : faults stor
ed, following § instruction and
check if fault appears again
Select asynchr
onous motor in parameters
Reload param
eters tables INxx
Corresponding to the door type controlled
(see § Notice: configuration following door type)
CAUSES
Memory
Fault
Connector disconnected in the unit
Ventilation fault or parametering fault
M
otor fault
Parametering fault
M
otor fault
Parametering fault
Faulty encoder
F
aulty m
otor
Faulty motor wiring
Mains power voltage superior to 270V
For heavy doors equipped with brushless motor
If deceleration time is too short
Mains power voltage inferior to 155 v
Hard and soft incompatibles
If brushless motor selected in parameters and
asynchronous motor installed.
Parameters do not corres
pond to the type of door
used
PR
OBLEMS MET
Err1 m
em
ory fault
Err2 (Mute power card)
Err3 (Excessive
temperature)
Err4 (Overcurrent)
Err5 (Overload)
Err6 (Motor or encoder fault)
Err7 (Mains power supply over-voltage)
Err8 ( Mains power supply undervoltage)
Err9 ( Logical and power card incompatibles)
Err10 (Hall effect sensor fault)
*** Com
m
ent : generally speaking, when a
door is operating abnormally , check, first, if
the parameters loaded suit the door type
controlled.