23 

 

Fast: average update of normal speed 

Slow: Update slowly with slightly longer average values 

 

Slow  settings  can  be  updated  slowly  for  fast  changing  sound 

signals to determine the location of the noise source. For a detailed 

description of the image average, see 'Beamforming Setting'. 

 

 

Gain Setting   

Depending on the amount of noise, user can set the appropriate 

gain value. User can select from 0, +10, +20, or +30 dB, and can 

apply the appropriate value depending on the size of the noise.   

 

A reasonable gain value for normal-sized noise measurements: 

+20 dB 

*The smaller the sound, the better it is to increase the gain 

value.

 

 

Hide 

Icon(Object) 

This  icon(object)  provides  a  clearer  picture  of  the  screen  being 

measured  by  hiding  the  objects  'Threshold',  'Image  Range', 

'Measurment File USB Transfer'and 'Gallery' on the right side of the 

screen. If user is using custom mode, the frequency setting slide 

will  be  also  hidden.  Touch  the  icon  (object)  one  more  time  to 

release the hidden processing. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

sales@GlobalTestSupply.com

Summary of Contents for BATCAM 2.0

Page 1: ...Portable Ultrasonic Camera BATCAM 2 0 User Manual www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 2: ...escription 10 I Power Device 10 II User Manual 10 III Portable Hard Case 10 IV Hand Strap 11 Software 12 I Main Screen User Interface 12 II Icon object and Function Description 13 III Beam Forming Setting 26 IV Additional Setting 28 V Product Management and A S 29 Product Specification 30 Components and other specifications 30 Product Certification 31 I Electromagnetic Compatibility 31 II FCC Comp...

Page 3: ...tions such as gas air leaks and electrical discharges with high speed FPGA based processors This document describes the components of BATCAM 2 0 and provides information on how the device works Product Configuration The BATCAM 2 0 product consists of the following www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 4: ...ATCAM 2 0 are shown below Connect External Device and How to Use the Device BATCAM 2 0 device body is equipped with an external device such as a monitor and a connector to connect the power cable as shown below www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 5: ...e HDMI connector to output the videos being filmed or stored to the monitor 4 USB Port User can copy data stored in BATCAM 2 0 to a USB memory device or update internal software II How to Connect Power Adaptor Connect the LEMO connector of the BATCAM 2 0 power adapter in the direction shown When using the LEMO connector connect and use the connector by aligning the power connector groove inside th...

Page 6: ...f the product as shown below Not Charged Charging Charging Complete 2 Power Status Indicator Top Left The Power Condition Indicator LED at the top left of the product can be used to check the power condition of the product Power ON Power OFF Green Light On Power ON Green Light Off Power OFF Red Charging Green Charging Complete www GlobalTestSupply com Find Quality Products Online at sales GlobalTe...

Page 7: ...T 32 format via the USB port Here s how to copy data The amount of time that is transferred may vary depending on the number and capacity of the files stored There is no USB memory device available on the product Connect the USB memory device to the USB port located on the left Connect the USB memory device and press the USB icon object on the right side of the BATCAM 2 0 main screen www GlobalTes...

Page 8: ...er press the power button again for 2 seconds to turn off the power and the power status indicator lamp off 1 Power ON When powered on the company logo SMI and product logo BATCAM appear in order on the LCD screen and the software operates 2 Power OFF When you turn off the power the product logo below appears on the LCD screen and ends its operation www GlobalTestSupply com Find Quality Products O...

Page 9: ...n the right side of the main screen 2 Save Video Press and hold the Record button 2 seconds to start filming the video AVI and an icon object appears at the top of the screen to indicate that you are recording as shown in the figure below on the right Press and hold the record button for 2 seconds to end the shoot and save the video automatically User can view saved videos by clicking the director...

Page 10: ... product 1 Light ON When the light is off and you press the icon object the light turns on immediately and the icon object is changed 2 Light OFF When the light is on pressing the icon object immediately turns off the light and changes the icon object Light ON Light OFF www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 11: ... to use the power units included in the product II User Manual BATCAM 2 0 User Manual This is a manual for BATCAM 2 0 users and provides a variety of use the product III Portable Hard Case BATCAM 2 0 Portable Hard Case Waterproof case for storing or carrying BATCAM 2 0 product and components It is recommended that you use it for storage and movement of product www GlobalTestSupply com Find Quality...

Page 12: ... which allows user to hold the product when measuring with hand as shown below Care must be taken not to drop the product when using straps BATCAM 2 0 Hard Case Interior Appearance and Storage Method www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 13: ...ncluding measurement mode distance between source and BATCAM 2 0 and gain settings Other settings include language time zone hide icon object measurement file USB transfer and gallery check delete measurement file settings as settings for user convenience and measurement efficiency The user can also estimate the degree of leakage occurring by the leakage quantity icon object at the top Checking th...

Page 14: ... of each icon object are shown in the table below Icon Object Function Description Language Timezone Check and Setting This icon object indicates the current date time In addition you can change the language of use as well as the time zone for each country by pressing and holding the icon object The method of change is as follows 1 Press and hold the icon object 2 www GlobalTestSupply com Find Qua...

Page 15: ...hen the Discard button is pressed the language time change will be invalidated pop up window closed Leakage Estimation Check Index This icon object indicates the amount of Leakage that is occurring Depending on the amount of leakage it will be changed to a suitable number icon object and the criteria for distinguishing icons objects are as follows Less than 200 cc m www GlobalTestSupply com Find Q...

Page 16: ...t shows the maximum beam power value of the noise being measured Beam Power is the color scheme in the form of a rainbow on the measurement screen which indicates the amount of sound pressure being measured Distance Setting This icon object allows the user to set the distance between the noise source or target being measured and the ultrasonic camera For accurate measurements it is recommended tha...

Page 17: ...3 m Ex Internal Memory Status Check The user can check the internal memory status of BATCAM 2 0 under the maximum beam power value and distance icon object It is divided into three colors green orange and red and the criteria for classification are as follows For your information the internal memory capacity of BATCAM 2 0 is about 53 GB Green Used less than 98 internal memory Orange Used more than...

Page 18: ...less than the set reference value the screen does not display the beam power For accurate measurements it is recommended that you check the display reference value settings before the measurement depending on your measurement environment The reference value can be set from 0 dB to 120 dB depending on the characteristics of the noise being measured and the measurement environment Measurement File I...

Page 19: ...asurement file Press this icon object to check or delete the measurement file image video of BATCAM 2 0 Press Images or Videos to see or delete the measurment images or videos Press Quit to return to the main screen and press Delete All to delete all files To delete only one file select the file and press the Delete button on the bottom right USB Memory Device is not connected www GlobalTestSupply...

Page 20: ...f measurement Maximum beam power value dB at time of measurement Display Base dB at time of measurement Image range value at time of measurement dB Amplification value at time of measurement dB Frequency band kHz set at time of measurement Image mean setting at time of measurement Estimated amount of leakage at time of measurement LFE index value www GlobalTestSupply com Find Quality Products Onli...

Page 21: ...iled description of the display threshold and image range refer to the Beam Forming Setting section At the bottom of the main screen there are five icons objects shown below The function definition and description of each icon object are as below Icon Object Function Description Battery Status Check This icon object allows the user to check the current battery status The battery status is expresse...

Page 22: ... a warning message below will appear If this warning message appears connect the BATCAM 2 0 power unit and charge it Once the power supply has stabilized the screen below will be switched to If the battery is charged more than 15 then BATCAM 2 0 can be used again www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 23: ...icrophone is blocked by alien substances Red Abnormal Ex All 112 microphones are normal Ex No 42 47 63 69 80 microphones are blocked by alien substances Image Average Setting Image average is another way of setting up the beam power image on the screen Depending on the type or characteristics of the noise user can set the appropriate image average There are two options in total and the selection c...

Page 24: ...ly the appropriate value depending on the size of the noise A reasonable gain value for normal sized noise measurements 20 dB The smaller the sound the better it is to increase the gain value Hide Icon Object This icon object provides a clearer picture of the screen being measured by hiding the objects Threshold Image Range Measurment File USB Transfer and Gallery on the right side of the screen I...

Page 25: ... the audible frequency area and is suitable for measuring human audible noise and joints User can listen to the sound sources measured in either ultrasonic or audible mode when user can adjust the volume of the audio output User can adjust the volume adjustment number by scrolling up and down the empty area the red display area below on the left side of the Measurment File USB Transfer icon object...

Page 26: ...mark Ultrasonic 25 kHz 40 kHz Auto Set Audible 4 kHz 20 kHz Auto Set Custom Set up by user When Custom mode is selected measurement frequency range can be set by user www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Page 27: ... the screen For accurate measurements it is recommended that you set the Threshold before measurements depending on your measurement environment The display reference value can be set from a minimum of 0 dB to a maximum of 120 dB depending on the nature of the noise you want to measure and the measurement environment The Threshold setting is set as the minimum value of the noise source you want to...

Page 28: ...aracteristics of the noise the user can set the appropriate average If there is no image average the current noise is immediately displayed on the screen If you look at the graph on the left the current noise is indicated by a black line and an orange dotted line shows the threshold The screen shows the part displayed by the rainbow colored chart and updates are made immediately for each frame tha...

Page 29: ...does not matter if there is a folder with a different name inside the USB Download latest software files to your PC or laptop The file extension is mender Copies downloaded files into the BATCAMV2_UPDATE folder created in 2 The downloaded update file name must be in the following structure BATCAMV2_UPDATE SMI BATCAMV2 v0 0 0 signed 2020xxxxxxxxxx mender v0 0 0 Firmware version xxxxxxxxxx Date Time...

Page 30: ...e product in its case when not in use 2 A S Free A S Free A S for one year from the date the customer receives the product provided that the following is a paid A S Paid A S In case the warranty period for free of charge has expired Defects caused by customer negligence or careless handling Defects caused by natural disasters accidents disasters etc Defects caused by external factors other than de...

Page 31: ...ion and Processing Sampling Rate 96 k S s Image Frame Rate 25 FPS Image Resolution 640 x 480 Internal Memory 53 GB About 25 MB for 5 minutes 7 days for continuous video storage Measurement Circumstances Operating Temperature Operating Humidity 20 50 C 10 85 Internal Batterypack Battery Type Battery Capacity Battery Operating Time Lithium ion battery pack 49 5 Wh 4 hours Components and other specif...

Page 32: ...product proves that it has been registered in accordance with paragraph 2 3 of Article 58 of the Radio Wave Act The Clause 3 Article 58 2 of Radio Waves Art V Battery This product uses lithium ion batteries Do not use the product in environments where it can be wet wet or corroded Do not store or place the product in or near the source of heat in a high temperature strong direct sunlight microwave...

Page 33: ...ct type there is a risk of explosion Do not attempt to remove or remove a battery that the user cannot replace If there is a problem with the battery The batteries contained in this product must be disposed of in accordance with local laws and regulations IEC 62133 2012 EN 62133 2013 UN 38 3 ST SG AC 10 11 Rev 6 Amend 1 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSuppl...

Page 34: ...Do not use this device outside of the range of temperature used appropriate temperature range 20 C to 50 C Do not use it in places where there are strong magnets power meters etc If you are connecting or disconnecting each cable or cord from the main body do not grab the part of the cable but hold the part of the plug and connect or disconnect it Do not allow foreign substances to enter the produc...

Reviews: