Status messages of active power limitation
Name
Display
Description
P-WModStt
Off
No mode for active power limitation has been selected.
WMax
Active power is limited by specification of an upper limit. This limit is
based on
Pmax
.
Hz
Active power is limited by a frequency increase.
Tmp
Active power is limited by temperature derating.
AmpPv
Active power is limited via a PV current limitation.
AmpAC
Active power is limited via an AC current limitation.
SMax
The active power is limited by the maximum apparent power.
Q-VAr
The active power is limited due to the priority of the reactive power
setpoint.
QEnsure
The active power is limited due to the intermediate storage of reac-
tive power.
P-Vtg
The active power is limited due to the characteristic curve P(V).
VdcMax
The active power is increased via the setpoint due to the DC voltage
being too high.
AmpPvOptiprot
For the order option "Optiprotect", the active power is limited due to
switch currents being too high.
Errors and warnings relating to the reactive power setpoint
Name
Display
Description
Q-VArModFailStt
Off
No mode for specifying the reactive power setpoint has been se-
lected.
Ok
A mode for specifying the reactive power setpoint has been selected
and no error is present.
ComFail
The mode
VArCtlCom
or
PFCtlCom
has been selected and the ex-
pected signal with a valid reactive power setpoint has been absent
for at least five minutes.
AnInFail
The mode
VArCnstNomAnIn
or
PFCnstAnIn
has been selected
and the value measured at the analog input is less than 2 mA.
ComInvalid
The mode
VArCtlCom
or
PFCtlCom
has been selected and there is
invalid content in the power setpoint information.