Name
Description
Value/range
Explanation
Default
value
SSM Identifier* Identification number of Sunny
String-Monitor
1 to 99
‒
0
Group String 1
*
Assigns strings to their respective
group
0 to 3
Parameter exists for all eight
groups
0
Group String*
All groups
0 to 3
‒
0
No.of String 1* Number of connected strings in
the respective group
1 to 4
Parameter exists for all eight
groups
If you wish to use this function,
contact us (see Section 17,
page 256).
‒
No.of Strings*
All groups
1 to 4
‒
‒
Monitoring1
On*
Start of monitoring of strings in
group 1
0:00 a.m. to
11:59 p.m.
Parameter exists for all eight
groups
Configure the string settings
preferably via the Sunny Cen-
tral String-Monitor Controller.
0
Monitoring1
Off*
End of monitoring of strings in
group 1
0:00 a.m. to
11:59 p.m.
Parameter exists for all eight
groups
Configure the string settings
preferably via the Sunny Cen-
tral String-Monitor Controller.
0
Monitoring On
*
Start of monitoring of strings in all
groups
0:00 a.m. to
11:59 p.m.
‒
0
Monitoring Off
*
End of monitoring of strings in all
groups
0:00 a.m. to
11:59 p.m.
‒
0
Kommando**
Stop
If you wish to use this function,
contact us (see Section 17,
page 256).
0
Mess
Offset1
Offset2
Diag
Reset Err.Cnt.
StoreCalibData
LoadCalibData
Watchdog Test
14 Operating Data and Parameters
SMA Solar Technology AG
System Manual
MVPS22JP-SH-en-11
238
Summary of Contents for 1000-1SC