Commissioning the Sunny Boy
SB1100U-11:SE1604
SMA America
5-5
Note:
If there is adequate irradiation, and the resulting input
voltage is high enough, the Sunny Boy automatically starts to
feed AC power to the household circuits and the grid.
Note:
The Sunny Boy operates from the power produced by the
PV array and is designed for minimal internal DC-power
consumption. The maximum power the Sunny Boy 1100U will
consume in normal operation is 4W.
Note:
Since the Sunny Boy operates from the power produced
by the PV array, you must take the power consumed by the
Sunny Boy into account when measuring the output voltage of
the PV array. When irradiation is at high levels, the relatively
negligible amount of power drawn by the Sunny Boy won’t be
noticeable, but when irradiation is marginal, the Sunny Boy’s
load will have a noticeable effect on the voltage reading.