Displays and Messages
SB1100U-11:SE1604
SMA America
6-19
Mode Messages
Stop: manual
system
stop
Offset:
offset calibration of the electronics
Waiting:
grid switching-on conditions are not fulfilled (yet)
Grid monitoring:
checking grid (grid impedance)
MPP-Search:
PV voltage is determined and set
MPP:
Sunny Boy is in MPP mode
V-Const:
Sunny Boy is in constant voltage mode
Derating:
reduction of the grid feeding power
Disturbance:
A condition is only considered a Disturbance for as long as the
reasons for this condition still are present.
Error:
A condition is considered an Error whenever the inverter cannot
restart without user interaction.
Summary of Contents for SB1100U