Displays and Messages
SB1100U-11:SE1604
SMA America
6-21
dZac-Bfr
dZac-Srr
The rate of change of the AC grid impedance is exceeding the permiss-
able range. („Bfr“ or „Srr“ is an internal message and is not important
for the user.) The Sunny Boy assumes that the public grid is down and
disconnects from the grid in order to avoid islanding.
If you therefore often observe „dZac-Bfr“ or „dZac-Srr“ consult the utility
company and ask, if it is permissable to change the grid monitoring pa-
rameters of the inverter. Contact SMA about how to change the grid
monitoring parameters of your Sunny Boy.
Imax
Overcurrent on the AC side. This failure code is indicated in case the cur-
rent to the AC grid exceeds the specification. This may happen in case of
harmfull interference on the grid. If you observe „F-Imax“ often, check
your grid. For assistance contact SMA.
VpvMax
DC input voltage above the tolerable maximum value
MSD-UAC
MSD-VAC
MSD-FAC
MSD-ZAC
Internal measurement comparison error: The Sunny Boy measured values
of BFR and SRR are too different from each other.
K1-Close
K1-Open
Relay test failed
EEPROM
Transition failure during reading or writing of data EEPROM, the data is
not essential for safe operation - this failure does not effect performan ce.
EEPROM p
Data EEPROM defective, device is set to permanent disable due to the
fact that the data loss affects important functions of the inverter. Contact
SMA.
OFFSET
Grid monitoring self-test failed.
MSD-Timeout
BFR or SSR controller failure
ROM
The internal test of the Sunny Boy Control system firmware failed. Contact
SMA in case you observe this failure often.
Watchdog
Watchdog for operation control triggered
Bfr-Srr
Communication between micro-controllers is failing
Shut-Down
Internal over current continuous
EarthCurMax-Srr
SRR-earth current between PV+ and GND is out of tolerable range
EarthCurMax-Bfr
BFR-earth current between PV+ and GND is out of tolerable range
GFDI Fuse Open
The GFDI-Fuse is defective or open
Error Code
Description
Summary of Contents for SB1100U
Page 1: ...Photovoltaic Grid Tied String Inverter Sunny Boy 1100U Installation Guide SOLARTECHNOLOGY...
Page 2: ......
Page 8: ...vi SMA America SB1100U 11 SE1604...
Page 12: ...Unpacking and Inspection 2 2 SMA America SB1100U 11 SE1604...
Page 44: ...Commissioning the Sunny Boy 5 6 SMA America SB1100U 11 SE1604...
Page 68: ...Displays and Messages 6 24 SMA America SB1100U 11 SE1604...
Page 72: ...Troubleshooting 7 4 SMA America SB1100U 11 SE1604...
Page 74: ......
Page 75: ......
Page 76: ......