Wiring and Connecting the Sunny Boy
Sunny Boy 1100U Internal Components
SB1100U-11:SE1604
SMA America
4-3
Figure 4-1 Sunny Boy 1100U Internal Component Locator
The DC input from the PV array (via the DC disconnect enclosure) and the output to the
AC utility grid connect to the inverter inside the Sunny Boy’s case. These internal AC and
DC wiring terminals (see Figure 4-1) accept a maximum wire size of #6 AWG.
Knockouts are provided on the bottom of the Sunny Boy near each of the terminals for
the wires to enter the case (Figure 4-2).
LEDs for
status display
Display
Terminal for optional
communication
(RS-232 or RS-485)
GFDI
Fuse Holder
AC Line
Terminals
(L1 and L2)
Socket for optional
communication Piggy-Back
(RS-232, RS-485 or Powerline)
Ground
Terminal
(PE)
Firmware EPROM
DC–
Terminal
(input from
PV array)
DC+
Terminal
(input from
PV array)