Displays and Messages
6-18
SMA America
SB1100U-11:SE1604
Measuring Channels and Messages
The communication options support a number of measuring channels and messages
from the Sunny Boy inverters.
The following abbreviations are used:
BFR
B
etriebs
f
ührungs
r
echner (Sequential Control System)
SRR
S
trom
r
egelungs
r
echner (Current Control System)
Measuring Channels
Vpv
:
PV input voltage
Vpv
Setpoint
:
desired input voltage of the Vpv-control
Iac
:
current to the grid
Vac
:
grid voltage
Fac
:
grid frequency
Pac
:
power fed to grid
Zac
:
grid impedance
Vpv-PE:
PV-voltage to earth
Ipv
:
current from PV-panels
E-Total (E-total)
:
total energy yield
h-Total (h-total)
:
total operation hours
Power On
:
total system start ups
Serial Number
:
Sunny Boy serial number
Mode
: operating
mode
Error
:
description of fault
Summary of Contents for SB1100U
Page 1: ...Photovoltaic Grid Tied String Inverter Sunny Boy 1100U Installation Guide SOLARTECHNOLOGY...
Page 2: ......
Page 8: ...vi SMA America SB1100U 11 SE1604...
Page 12: ...Unpacking and Inspection 2 2 SMA America SB1100U 11 SE1604...
Page 44: ...Commissioning the Sunny Boy 5 6 SMA America SB1100U 11 SE1604...
Page 68: ...Displays and Messages 6 24 SMA America SB1100U 11 SE1604...
Page 72: ...Troubleshooting 7 4 SMA America SB1100U 11 SE1604...
Page 74: ......
Page 75: ......
Page 76: ......