Setting String Current Monitoring Parameters
SMA
Technologie AG
Page 46
SSM-TEN072310
Technical Description
Under
"Device Set-up...SMUs...Devices...Parameters"
, the number of
connected strings per measuring channel used can be entered.
"Device Set-up...SMUs...Devices...Parameters"
[ Parameters]
No.of Strings 1
......2
No.of Str. All
......1
Information
The number of strings per channel is freely selectable for the eight measuring
channels. The default setting is 1. The maximum number of strings is limited to
4.
Information
Under "
No.of Str. All"
, all channels of the SSM-C can be given a string
count of one to four. This avoids having to set the number of strings for each of
the individual channels, since this is automatically set for all the individual
channels.
Information
If no strings are attached to a measuring channel, this channel must be
allocated to group zero, since the string current monitoring is deactivated for
this group. This is necessary to ensure that this measuring channel is not
included in the averaging process.