9 Installing the Left Enclosure Lid
SMA Solar Technology AG
Replacement Manual
STPxxx-60-DC-SPD-RM-xx-11
19
4. Fasten the 4 marked fixing screws on the DC SPD
(PH2, torque: 1.5 Nm). For this, use the additional 4
screws (M4) included in the scope of delivery.
5. Fasten all 24 cables on the DC SPD with 20 M4
screws (PH2, torque: 1.5 Nm) and 4 M5 screws
(PH2, torque: 2.6 Nm) from the scope of delivery.
Ensure that the cables are connected according to
the label on the DC SPD.
6. Ensure that all cables are tight and that the screws are not twisted.
7. Reconnect and lock the ribbon cable connector.
8. Reinstall the left enclosure lid (see Section 9, page 19).
9
Installing the Left Enclosure Lid
1. Ensure that the seal and contact plates on the inside of the enclosure lid are undamaged.
2. If necessary, remove any remains of the seal and dirt from the edge of the inverter enclosure.
3. Attach the left enclosure lid with 4 M6x14 screws.
Loosely tighten all screws.
1
2
4x
4x
ENGLISH
Summary of Contents for STP 110-60
Page 65: ...1 SMA Solar Technology AG STPxxx 60 DC SPD RM xx 11 65 1 5 1 6 X703 1 X703 6 10...
Page 68: ...2 SMA Solar Technology AG STPxxx 60 DC SPD RM xx 11 68 5 5...
Page 69: ...2 SMA Solar Technology AG STPxxx 60 DC SPD RM xx 11 69 DC DC AC DC 1100 V...
Page 70: ...2 SMA Solar Technology AG STPxxx 60 DC SPD RM xx 11 70 DC 5 C v v...
Page 221: ......