13 Technical Data
SMA Solar Technology AG
Operating manual
STP3-6-3AV-40-BE-en-13
99
STP5.0-3AV-40
STP6.0-3AV-40
MPP voltage range
215 V to 800 V
260 V to 800 V
Rated input voltage
580 V
580 V
Minimum input voltage
125 V
125 V
Initial input voltage
175 V
175 V
Maximum input current, input A
12 A
12 A
Maximum input current, input B
12 A
12 A
Maximum short-circuit current,
input A*
18 A
18 A
Maximum short-circuit current,
input B*
18 A
18 A
Maximum reverse current into
the PV array
0 A
0 A
Number of independent MPP
inputs
2
2
Strings per MPP input
1
1
Surge category in accordance
with IEC 60664-1
II
II
* In accordance with IEC 62109-2: ISC PV
AC Output
STP5.0-3AV-40
STP6.0-3AV-40
Rated power at 230 V, 50 Hz
5000 W
6000 W
Maximum apparent AC power at cos φ = 1
5000 VA
6000 VA
Rated grid voltage
230 V
230 V
Nominal AC voltage
3/N/PE, 220 V /
380 V, 230 V /
400 V, 240 V / 415 V
3/N/PE, 220 V /
380 V, 230 V /
400 V, 240 V / 415 V
AC voltage range*
180 V to 280 V
180 V to 280 V
Nominal AC current at 220 V
3 x 7.6 A
3 x 9.1 A
Nominal AC current at 230 V
3 x 7.3 A
3 x 8.7 A
Nominal AC current at 240 V
3 x 7.0 A
3 x 8.4 A
Maximum output current
3 x 7.6 A
3 x 9.1 A
Total harmonic distortion of the output current
with total harmonic distortion of the AC voltage
<2%, and AC power >50% of the rated power
< 3%
< 3%
Summary of Contents for STP3.0-3AV-40