SMA Solar Technology AG
9 Service
Installation Manual
STPS60-IA-xx-13
41
2052
Get grid
code
Transmission of the Grid Code
from the SMA Inverter
Manager to the inverter has
started.
None
-
-
-
2053
Get grid
code done
Transmission of the Grid Code
from the SMA Inverter
Manager to the inverter has
ended.
None
-
-
-
2054
Grid code
TFTP failed
Transmission of the Grid Code
from the SMA Inverter
Manager to the inverter has
failed.
If this event occurs frequently,
contact Service.
-
-
-
2055
Fallback
activated
The inverter switched to the
fallback mode after the
communication with the SMA
Inverter Manager was
interrupted.
None
-
-
-
2056
Fallback
ended
The inverter has switched back
to normal operation after
having been in the fallback
mode due to a communication
disturbance with the SMA
Inverter Manager.
None
-
-
-
2057
Fetching
battery
limits over
TFTP
Fetching new battery limits via
TFTP has started
None
-
-
-
2058
Fetching
battery
limits
completed
Fetching new battery limits via
TFTP completed successfully
None
-
-
-
2500
BMS error
Error of the battery
management
Contact the battery manufacturer.
-
-
x
2501
BMS
warning
Warning of the battery
management
Contact the battery manufacturer.
-
-
x