SMA Solar Technology AG
11 Technical Data
Installation Manual
STPS60-IA-xx-13
47
Table 5.2 Safety specifications
1)
depending on local regulations
11.2 Compliance
Electrical safety
• IEC 62109-1/IEC 62109-2 (Class I, grounded –
Communication part Class II, PELV)
Functional
Functional Safety
• Voltage and frequency monitoring
• Monitoring of DC current share in AC current
• Insulation resistance monitoring
• FI monitoring
Islanding detection - grid failure
• Active frequency shift
• Disconnection
• Three-phase monitoring
• ROCOF/SFS
RCD compatibility
1)
Type B, 1000 mA
Parameters
STPS60-10
International standards
STPS60-10
Efficiency
Peak efficiency, standard: EN 50530
EC low-voltage directive
2014/35/EU
EC directive for electromagnetic compatibility (EMC)
2014/30/EU
Certainty
EN 62109-1:2010/EN 62109-2:2011
Functional Safety
EN 62109-2:2011
EMC, interference immunity
EN 61000-6-2:2005
EMC, emission
EN 55011:2016 Group 1, Class A
Harmonic currents
EN 61000-3-12
CE
Yes
Properties of the supply grid
IEC 61727
EN 50160