Sunny Boy 2000
Technical Description
SB2000-11:EE
- 21 -
SMA Regelsysteme GmbH
Fig. 3.3: Mounting to wall, side view
Metal straps for mounting:
The top straps take the load, the
bottom is screwed down in order to
prevent tilting off the wall.
Securing the Sunny Boy against lifting up: After the Sunny Boy has been
hanged into the top screws fasten
the bottom screw to secure against
lifting up.
Mounting to the wall
•
Mark the holes with the drilling template.
•
Drill the holes (and put in the dowels), put in the screws of both top holes and
screw them in until ca. 4 mm are looking out.
•
Hang the inverter into the two top screws.
•
Fasten the bottom screw in order to prevent lifting up.
•
Check the mounting of the inverter.