Sunny Boy 2000
Technical Description
SB2000-11:EE
- 75 -
SMA Regelsysteme GmbH
Parameter List Sunny Boy 2000
All parameters are transmitted to Sunny Data or Sunny Boy Control when configuring
the Sunny Boy 2000. The following table lists the parameters which can be displayed
and changed:
No.
Name
Unit
Valid Range
Default Value
Changeable by
From...
to...
1 SMA-SN
-
Fixed
2 U
PV
-Start V
140
500
150
Installer
3 T-Start
S
5
300
10
Installer
4 U
PV
-Stop V
100
500
110
Installer
5 T-Stop
S
1
300
2
Installer
6 Usoll-Konst
V
140
500
450
Installer
23 NiTest
0
1
1
Installer
28 Uac-Min
V
180
300
198
Installer
29 Uac-Max
V
180
300
251
Installer
30 Fac-Min
Hz
49
51
49.81
Installer
31 Fac-Max
Hz
49
51
50.19
Installer
32 Zac-Max
m
Ω
0
20000
1700
Installer
33 DZac
m
Ω
0 2000
350 Installer
43 Hardware-BFS
Version
fixed
44 Software-BFR
Version
fixed
45 Software-SRR
Version
fixed
68 Operation
mode
MPP-Operation Installer
69 Storage
function
none
Installer
Table 9.1: Sunny Boy 2000 Parameter List