Sunny Boy 2000
Technical Description
SB2000-11:EE
- 23 -
SMA Regelsysteme GmbH
Preparing the connection
The front panel of the inverter must be removed in order to attach the output wiring -
this is done by removing the four screws (M5) accessible from the front.
The front panel is grounded with a tab and receptacle connector - care-
fully remove the green-yellow cable in order to remove the front panel.
You can now see the position of relevant modules and clamps in the open case in
front of you. You will find:
•
The plug connectors for PV-panel connection
•
The mains terminals (in the lower middle to right section)
•
The mains fuse (in the lower middle to right section)
+
+
mains connectors
mains fuse
(12.5 A, slow blow)
PV-panel connectors
thermally monitored
varistors
Fig. 3.4: Connectors in the Sunny Boy 2000