Display

SMA Solar Technology AG

12

SB33_38-BA-BEN114230

User Manual

4 Display

4.1 Operation

The display shows the current values of your plant. The displayed values are updated every 
5 seconds.
You can operate the display by tapping the enclosure lid:

Single tap:

The backlight is switched on. After 2 minutes, the backlight switches off.

2 taps in quick succession (valid from firmware version 4.00):

The inverter successively displays the device type, the firmware version and the configured country 
setting.

4.2 Display Messages during Operation

After commissioning, the inverter successively displays the device type, the firmware version and the 
configured country setting. If you want to view the display messages of the startup phase again while 
the inverter is in operation, double tap the enclosure lid (from firmware version 4.00).

Upon error-free connection of the inverter to the power distribution grid, after approximately one 
minute, the display starts alternating between the messages shown below. Each message appears for 
5 seconds, and then the cycle restarts from the beginning.

Display message

Description

Inverter device type

Firmware version of internal processors

Default national standard of inverter, example: 
"GER/VDE0126-1-1"

SB xxx

Wrxxx

Summary of Contents for SUNNY BOY 3300

Page 1: ...SB33_38 BA BEN114230 TBEN SB33 38 11 Version 3 0 EN PV Inverter SUNNY BOY 3300 3800 User Manual...

Page 2: ......

Page 3: ...Safety Precautions 8 2 3 Explanation of Symbols 9 2 3 1 Symbols on the Inverter 9 2 3 2 Symbols on the Type Label 10 3 Product Overview 11 4 Display 12 4 1 Operation 12 4 2 Display Messages during Op...

Page 4: ......

Page 5: ...devices SB 3300 11 SB 3800 11 1 2 Target Group This manual is intended for the operator 1 3 Additional Information You will find additional information on the device specific technical data in the ins...

Page 6: ...ided will directly result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a hazardous...

Page 7: ...erating range of all components at all times The free design program Sunny Design www SMA de en SunnyDesign will assist you The manufacturer of the PV modules must have approved the PV modules for use...

Page 8: ...only be carried out by an electrically qualified person Electrical installation Repairs Modifications CAUTION Risk of burns through contact with the enclosure during operation Only touch the enclosure...

Page 9: ...tive Inform your installer An error has occurred Inform your installer immediately You can operate the display by tapping the enclosure lid Single tap The backlight switches on or the display scrolls...

Page 10: ...tion that accompanies the inverter The inverter must not be disposed of together with the household waste Further information on disposal can be found in the enclosed installation manual CE marking Th...

Page 11: ...Position Designation A Enclosure lid B Display C LEDs Green LED Operation Red LED Ground fault or varistor defective Yellow LED Fault D Fan guard E Type label for the identification of the inverter vi...

Page 12: ...during Operation After commissioning the inverter successively displays the device type the firmware version and the configured country setting If you want to view the display messages of the startup...

Page 13: ...e current values of the reactive power Qac and of the displacement power factor cos PF are displayed Total amount of energy fed in Total number of operating hours in feed in operation Display message...

Page 14: ...r feed in All LEDs are flashing The inverter is in the startup phase Green LED is on The inverter is feeding in to the power distribution grid Green LED is flashing This flashing can have the followin...

Page 15: ...lly monitored varistors on the DC input side is defective Inform your installer Yellow LED is on The inverter is in the operating state Permanent shutdown This can have several causes Inform your inst...

Page 16: ...our installer if you find any damage Do not perform any repair work yourself Maintenance and Cleaning Ask your installer to check for correct inverter operation at regular intervals If the inverter is...

Page 17: ...or safety reasons and ensures that the inverter does not connect to the power distribution grid Inform your installer Error An error has been detected Inform your installer Grid monitoring Grid monito...

Page 18: ...of the present disturbance error h on Total operating hours h total Total number of operating hours in feed in operation Iac Grid current Ipv Direct current Is Apparent current Power On Total number...

Page 19: ...ion unit The Electronic Solar Switch must be securely inserted into the bottom of the inverter and may only be removed by an electrically qualified person MPP Maximum Power Point Operating point of th...

Page 20: ...h the necessary assistance Inverter device type Inverter serial number Type and number of the PV modules connected Blink code or display message of the inverter Optional equipment e g communication pr...

Page 21: ......

Page 22: ......

Page 23: ...roduct under incorrect safety or protection conditions Altering the product or supplied software without authority The product malfunctions due to operating attached or neighboring devices beyond stat...

Page 24: ...USBMJB 1UZ UE XXX 4 VTUSBMJB DPN BV 4 FOFMVY 413 XXX 4 FOFMVY DPN 4 FJKJOH PNNFSDJBM P UE XXX 4 IJOB DPN 4 FDI 3FQVCMJD T S P XXX 4 FDI DPN 4 SBODF 4 4 XXX 4 SBODF DPN 4 FMMBT XXX 4 FMMBT DPN 4 C SJDB...

Reviews: