Technical Data
SMA Solar Technology AG
36
SB3300TLHC-IEN094121
Installation Guide
11 Technical Data
PV generator connection data
Setting
Max. input voltage
U
DC max
750 V
a)
Input voltage, MPP range
Upv
125 V ... 600 V
Max. input current
I
PV max
11 A
Max. input power
P
DC
3440 W
Voltage ripple
U
pp
< 10 % of the input voltage
Internal consumption during operation
< 10 W (standby)
a) The maximum open circuit voltage, which can occur at a cell temperature of -10 °C, must not exceed the maximum input
voltage.
Grid Connection Data
Setting
Nominal output power
P
ACnom
3000 W
Max. output power
P
ACmax
3300 W
Nominal output current
I
ACnom
13 A
Max. output current
I
AC max
16 A
Max. fuse protection
32 A
Harmonic distortion of output current
(at T
HD
< 2 %, P
AC
> 0.5 P
ACNom
)
K
IAC
< 4 %
Nominal AC voltage
U
ACnom
220 V / 230 V / 240 V
Voltage range
(extended operating range)
U
AC
180 ... 260 V AC
AC- Grid frequency
f
ACnom
50 Hz
Frequency range
(extended operating range)
f
AC
45.5 ... 52.5 Hz
Power factor (at nominal output power) cos Phi
1
Overvoltage category
III
Test voltage (50 Hz)
1.65 kV
Test surge voltage
4 kV (serial interface: 6 kV)
Internal consumption in night mode
0.25 W