5 Product Overview
SMA Solar Technology AG
Operating manual
SB55-LV-JP-41-BE-en-13
19
LED signal
Explanation
The green LED is flashing
(two seconds on and
two seconds off)
Waiting for feed-in conditions
The conditions for feed-in operation are not yet met. As soon as the
conditions are met, the inverter will start feed-in operation.
The green LED flashes
quickly
Update of central processing unit
The central processing unit of the inverter is being updated.
The green LED is glowing
Feed-in operation
The inverter feeds in with a power of at least 90%.
The green LED is pulsing
Feed-in operation
The inverter is equipped with a dynamic power display via the green
LED. Depending on the power, the green LED pulses fast or slow. If
necessary, you can switch off the dynamic power display via the
green LED.
The green LED is off
The inverter is not feeding into the utility grid.
The red LED is glowing
Event occurred
If an event occurs, a distinct event message and the corresponding
event number will be displayed in addition on the product user inter-
face or in the communication product (e.g. SMA Data Manager).
The blue LED flashes slowly
for approx. 1 minute
Communication connection is being established
The product is establishing a connection to a local network or is es-
tablishing a direct connection to an end device via Ethernet (e.g.
computer, tablet PC or smartphone).
The blue LED flashes quickly
for approx. two minutes
(0.25 s on and 0.25 s off).
WPS active
The WPS function is active.
The blue LED is glowing
Communication active
There is an active connection with a local network or there is a di-
rect connection with an end device via Ethernet (e.g. computer,
tablet PC or smartphone).