Installation
SMA
Technologie AG
Page 28
SB25_30-11:SE0307
Installation Guide
Connecting the AC Output with PG16
To connect a cable with a cross-section between 13.5 mm² and 16 mm², proceed as
follows.
1.
First of all, slide the pressure screw with the PG16 screw fitting (1) onto the cable.
Now slide the threaded sleeve (2) over the cable.
2.
Now connect the individual conductors to the socket element in sequence.
- Protective earth PE (green/yellow) to the
screw terminal with the earth sign.
- Neutral conductor N (blue) to screw terminal
1.
- Live L (brown or black) to screw terminal 2.
- Terminal 3 remains unused.
3.
Make sure the wires (3) are securely
connected.
4.
Now screw the threaded sleeve (4) onto the socket element (5) and tighten it.
(2)
(1)
PE
N
L
(3)
(4)
(5)