6-16
SMA America
SB700U-11:SE3207
Communication Options
Sunny Boy inverters are available with different communication options depending
upon your needs. The Sunny Boy series allows for both internal and external
metering options to be used simultaneously. These options may also be installed in
the field by qualified personnel.
PC Applications and Monitoring
Sunny Boy operating data may be transmitted to, and stored in, a remote system or
PC by one of the following methods:
• RS-485: Data from up to 50 inverters is sent via RS-485 cable to a remote control unit
or to a PC. Maximum length of cable is 4000’ (1200 m). An RS-485/232 converter
may be necessary for communication with a PC.
• Wireless: Data from up to 4 inverters is sent to the Sunny Beam by means of an an-
tenna installed in the Sunny Boy. Communication distance is dependent upon obstruc-
tions and the radio environment.
Sunny Data Control
This PC application is used to communicate with the Sunny Boy Control products. It
can be used to monitor multiple inverters, download historical system data and
adjust system parameters. It can also send system data to the Sunny portal server
via analog modem or ethernet.
Sunny Boy Control Plus
The Sunny Boy Control Plus provides continuous monitoring and data acquisition of
your PV system.
Sunny Beam
The Sunny Beam is a wireless desktop system monitor. It works together with the
Sunny Beam Piggy-Back card and provides wireless communication with up to four
Sunny Boys in the PV plant. Its graphical display shows a bar chart of actual power
production as well as daily and total-energy-yields in a single window.
Sunny WebBox
The Sunny WebBox is a link between the PV-plant and the operator or owner. The
direct connection to the Sunny Portal via internet gives you entirely new possibilities
for data acquisition and evaluation as well as the visualization on a PC with an
internet browser. No additional software needs to be installed.
Summary of Contents for Sunny Boy SB 700U
Page 1: ...Sunny Boy SB 700U Installation Guide Version 1 1 SB700U 11 SE3207 TBE SB07U...
Page 2: ...ii SMA America SB700U 11 SE3207...
Page 14: ...1 6 SMA America SB700U 11 SE3207...
Page 16: ...2 2 SMA AmericaSB700U 11 SE3207...
Page 24: ...3 8 SMA America SB700U 11 SE3207 11 Verify that the Sunny Boy 700U is firmly mounted in place...
Page 46: ...4 22 SMA America SB700U 11 SE3207...
Page 50: ...6 2 SMA America SB700U 11 SE3207 Figure 6 1 The Sunny Boy LED Status Indicator...
Page 84: ...8 6 SMA America SB700U 11 SE3207...
Page 85: ......