Nominal
Freq. (Hz)
Trip Limit (Hz)
Trip Frequencies (Hz)
Trip Times (s)
60
> 60.5
60.45 - 60.55
max. 0.1602
< (57.0 - 59.8)
(default 59.3)
56.95 - 59.85
(default 59.25 - 59.35)
adjustable 0.16 - 300
(default max. 0.1602)
< 57.0
56.95 - 57.05
max. 0.1602
Nominal
Voltage (V)
Trip Limit
Trip Voltages
Line-to-Neutral (V)
Trip Voltages
Line-to-Line
(V)
Trip Times (s)
120
50 %
88 %
110 %
120 %
57.6 - 62.4
103.2 - 108.0
129.6 - 134.4
141.6 - 146.4
N/A
max. 0.1602
max. 2.002
max. 1.001
max. 0.1602
SB700U-11:SE3207
SMA America
8-5
Trip Limits / Trip Times
Manufacturer’s Accuracies:
Terminal
in. lbs.
Nm.
Wire Size
AC Terminal Blocks
15
1.7
6 - 14 AWG
DC Terminal Blocks
15
1.7
6 - 10 AWG
Protective Earth Terminal
Blocks
15
1.7
6 - 14 AWG
• Trip Limit Accuracy: ± 2 % of nominal grid voltage
• Trip Time Accuracy: ± 0.1 % of nominal trip time
• Trip Frequency Accuracy: ± 0.1 % of nominal frequency
Torque Values and Wire Sizes
Summary of Contents for Sunny Boy SB 700U
Page 1: ...Sunny Boy SB 700U Installation Guide Version 1 1 SB700U 11 SE3207 TBE SB07U...
Page 2: ...ii SMA America SB700U 11 SE3207...
Page 14: ...1 6 SMA America SB700U 11 SE3207...
Page 16: ...2 2 SMA AmericaSB700U 11 SE3207...
Page 24: ...3 8 SMA America SB700U 11 SE3207 11 Verify that the Sunny Boy 700U is firmly mounted in place...
Page 46: ...4 22 SMA America SB700U 11 SE3207...
Page 50: ...6 2 SMA America SB700U 11 SE3207 Figure 6 1 The Sunny Boy LED Status Indicator...
Page 84: ...8 6 SMA America SB700U 11 SE3207...
Page 85: ......