Sunny Boy 1800U
Installation and Operator’s Manual
SB2500U-11:NE
-
27
-
SMA Regelsysteme GmbH
4.1 Operation Indicator
Standby (night)
all LEDs are off
The Sunny Boy is in “Standby” mode. The input voltage is too low
(V
PV
< 94 V) for supplying the Sunny Boy control system with enough power.
Initialization
all LEDs are on
The Sunny Boy control system is initializing.
The string voltage to the inverter is between approx. 94 V and 147 V. The supply is suffi-
cient for the system control and not quite sufficient for feeding to the grid. Data transmis-
sion is not possible.
NOTE:
In some seldom cases (bad weather, low solar radiation) the LEDs
can go on all at once and off again. This “blinking” results from the fact
that the incoming radiation is not high enough for the Sunny Boy to keep it
stable. Note: This is not a malfunction!