Sunny Boy 1800U
Installation and Operator’s Manual
SB2500U-11:NE
-
29
-
SMA Regelsysteme GmbH
Operation
Green LED on
Red LED off
Yellow LED off all LEDs are off
The Sunny Boy is feeding the local electricity grid, either in “MPP“ or in „Constant - Volt-
age“ operation.
•
„MPP“-operation (default setting):
The Sunny Boy pushes the voltage from the PV-modules to the voltage with the
maximum output power.
•
„Constant Voltage“-operation
The voltage from the PV-modules can be set to a fixed value. This value is transmit-
ted to the Sunny Boy with the Sunny Boy Control or with the Sunny Data software
(The parameter is “V-Konst“).
Derating
Green LED blinks (75% ON, 25% OFF)
Red LED off
Yellow LED off
The Sunny Boy is feeding the local electricity grid, either in “MPP“ or in „Constant - Volt-
age“ operation. Additionally it is in the derating mode due to increased temperature of the
heat sink.