Sunny Boy 1800U
Installation and Operator’s Manual
SB2500U-11:NE
-
42
-
SMA Regelsysteme GmbH
Mode Messages
Stop
manual system stop
Offset
offset calibration of the electronics
Waiting
grid switching-on conditions are not fulfilled (yet)
Grid monitoring
checking grid (grid impedance)
MPP-Search
PV voltage is determined and set
MPP
Sunny Boy
is in MPP mode
V-Const
Sunny Boy
is in constant voltage MPP mode
Derating
reduction of the grid feeding power
Disturbance failure
Error messages
F-Bfr-Srr communication
between
micro-controllers is failing
F-EEPROM
EEPROM cannot be read or written on
F-EEPROM dBh
EEPROM cannot be read or written on
F-Fac-Bfr BFR-frequency
measurement - value out of tolerable range
F-Fac-Srr
SSR-frequency measurement - value out of tolerable range
F-dZac-Bfr BFR-impedance
measurement - value out of tolerable range
F-dZac-Srr
SSR-impedance measurement - value out of tolerable range
F-Imax internal
over
current
F-Shut-Down
internal over current continuous
F-MSD-UAC
different values between BFR and SRR for grid voltage
F-MSD-FAC
different values between BFR and SRR for grid frequency
F-MSD-Meas
different values between BFR and SRR for dI, Fac, Vac or Zac
F-K1-Close
Relay test failed
F-K1-Open
Relay test failed
F-EarthCurMax-S
SRR-earth current between PV- and GND is out of tolerable range
F-EarthCurMax-B BFR-earth
current
between PV- and GND is out of tolerable range
F-MSD-ZAC
different values between BFR and SRR for grid impedance
F-Offset
Offset check for grid voltage failed
F-MSD-Timeout
BFR or SSR controller failure
F-Vac-Bfr
BFR-grid voltage measurement - value out of tolerable range
F-Vac-Srr
SSR-grid voltage measurement - value out of tolerable range
F-VpvMax
PV input voltage out of tolerable range
F-Zac-Bfr
BFR-grid impedance measurement - value out of tolerable range
F-Zac-Srr
SSR-grid impedance measurement - value out of tolerable range
F-Watchdog
Watchdog for operation control triggered
F-GFDI Fuse Ope
The GFDI-Fuse is defective
F-ROM
Failure of Read only memory test