Sunny Boy 1800U
Installation and Operator’s Manual
SB2500U-11:NE
-
55
-
SMA Regelsysteme GmbH
Parameter List Sunny Boy 1800U
All parameters are transmitted to Sunny Data or to the Sunny Boy Control when the Sunny
Boy is configured. The following table shows the available parameters:
No.
Name
Unit
Range
Default
Change by ...
from ...
to...
1 SMA-SN
-
Fixed
2 Vpv-Start
V
150 400
190
Installer
3
T-Start
S 5 300 300 Installer
5 T-Stop
S
1 1800
2
Installer
6 V-Const
Setval V
150 400
400
Installer
Plimit
W
1800 Fixed
23 Testcurrent
Zac mA
0
15000
8000
Installer
28 Vac-Min
V
90
150
107
Installer
29 Vac-Max
V
90
150
130
Installer
30 Fac-delta-
Hz
0
4.5
0.69
Installer
31 Fac-delta+
Hz
0
4.5
0.49
Installer
dFacmax
Hz/s 0.005 4.0
0.5 Installer
32 Zac-Max
mOhm
0
20000
20000
Installer
33
dZac
mOhm 0 20000 20000 Installer
43 Hardware-BFS Version
Fixed
44 Software-BFR Version
Fixed
45 Software-SRR Version
Fixed
68 Operating
mode
MPP-operation
Installer
69 Memory
func-
tion
no
function
Installer
Default
USA
60Hz
Installer
Storage
permanent
Installer
Table 7.2:
Parameter list Sunny Boy 1800U