Measurement channels and messages
SMA America, LLC
32
SB_CL_US-BUS094410
User Manual
REL_INV_OPEN
REL_GRID_OPEN
A grid relay does not open. The inverter checks the relays connecting it to
the grid before feeding power into the grid. If the grid relays do not function
properly, the inverter does not connect to the grid for safety reasons.
Corrective measures
• If this fault message is displayed repeatedly, it means that inverter
operation is permanently disabled. If the inverter is equipped with a
communication interface, the installer can try to rectify the fault with
the help of a communication product.
• Should this be unsuccessful, contact the SMA Serviceline.
Riso
The electrical insulation of the PV system to ground is faulty. The resistance
between the DC plus and/or DC minus connection and ground is outside
the defined limit range.
Corrective measures
• Contact your installer to check whether your system is properly
insulated or a ground fault has occurred. Further information is to be
found in the inverter installation guide.
Riso-Sense
The insulation measurement has failed.
Corrective measures
• Contact your installer or the SMA Serviceline if this problem recurs.
ROM
The inverter firmware is faulty.
Corrective measures
• Contact your installer or SMA if this problem recurs.
SD-DI-Conv
The inverter has detected an insulation fault on the DC side.
Corrective measures
• Contact your installer to check whether the plant is properly insulated
or a ground fault has occurred. Further information is to be found in
the inverter installation guide.
SD-Imax
The inverter has detected an overcurrent on the AC side. It disconnects from
the grid for safety reasons and then attempts to reconnect to the grid.
Corrective measures
• Contact your installer or the SMA Serviceline if this problem recurs.
SD-INV-Bridge
The inverter has detected a fault in the power electronics. It disconnects
from the grid and then attempts to reconnect to the grid.
Corrective measures
• Contact your installer or the SMA Serviceline if this problem recurs.
Shutdown
Temporary inverter fault.
Corrective measures
• Contact your installer or SMA.
Message
Description and corrective measure