Operating modes
SMA America, LLC
14
SB_CL_US-BUS094410
User Manual
3.1 LED operation indicators
3.1.1 All LEDs are off
Overnight shutdown
The inverter is in standby mode because the input voltage
is too low for operation.
If this operating mode occurs during a sunny day with
good irradiation, have the PV voltage checked by your
installer.
3.1.2 All LEDs are on
Initialization
The inverter is initializing. The power from the array is
sufficient to initialize control power, but not yet powerful
enough to begin normal operation. Data transmission is
not possible during initialization.
Occasionally, during inclement weather or low
irradiation, the LEDs may all turn on at once and then go
off again. This indicates that the inverter is trying to
initialize but the power available from the array is not
sufficient for normal operation. This is not a malfunction.
If no LED, or only the green LED is on or blinking, the inverter is operating normally. If all 3 LEDs are
lit up simultaneously, this is also an indication of normal operation ("initialization"). All other signals
are a sign of faulty operation.
3.1.3 The green LED is blinking rapidly
Starting
The inverter has sufficient PV power to calibrate its
internal systems, but not enough to begin normal
operation. Typically, the calibration lasts less than 10 sec.
and then the inverter resumes normal operation. PV
voltage must remain > PV Start Voltage setting for the
period of the P-Start parameter setting. The inverter will
also show this status if it has been manually set to STOP
mode.