3.2.3 The yellow LED blinks twice
Grid failure
The yellow LED is on for 5 sec., out for 3 sec. and then blinks twice. The code is repeated 3 times. This
code sequence will repeat as long as there is a grid fault condition.
This code can be caused by any of the following conditions:
• Low Grid Voltage (<Vac Min)
• High Grid Voltage (>Vac Max)
• Low Grid Frequency (< fac Min)
• High Grid Frequency (>fac Max)
• Rapid change in grid frequency or voltage
Check the condition of the grid at the AC terminal blocks within the Sunny Boy. Also inspect the AC
disconnect between the Sunny Boy and the grid.
WARNING
During operation, high voltages are present in the Sunny Boy.
Death or serious injury due to electric shock.
• The grid connection to the Sunny Boy must be checked by qualified personnel.