Operating modes
SMA America, LLC
18
SB_CL_US-BUS094410
User Manual
3.2.4 The yellow LED blinks 4 times
The yellow LED is on for 5 sec., remains off for 3 sec. and then blinks 4 times. The code is repeated
3 times. If the condition remains the code will continue to be sent.
The inverter has detected a DC input voltage that is too high for safe operation.
3.2.5 The yellow LED blinks 5 times
Device fault
The yellow LED is on for 5 sec., remains off for 3 sec. and then blinks 5 times. The code is repeated
3 times. If the condition remains the code will continue to be sent.
The inverter has encountered an internal fault that prohibits normal operation and will most likely
require servicing.
Contact SMA for assistance.
NOTICE
Destruction of the inverter caused by high DC input voltage.
• Contact your installer, who will immediately disconnect the PV generator from the
inverter and check the DC voltage, as described in the inverter installation guide.
• Always test the DC voltage at the DC disconnect switch before energizing the Sunny
Boy.