Operating modes
SMA America, LLC
20
SB_CL_US-BUS094410
User Manual
3.2.7 The yellow LED blinks 7 times
Drastic change in differential current
The yellow fault LED lights up for 5 sec. when the fault occurs, and then starts emitting the following
blink code. 3 sec. off and then 7 brief consecutive blinks. This code is emitted 3 times in succession.
If this fault is still present, the fault signal starts over again.
The Sunny Boy has detected a drastic change in differential current and immediately stopped feeding
into the grid. The integrated all-pole-sensitive residual current monitoring unit monitors the differential
current relative to ground from the inverter supply connection right through to the PV generator. This
additional personal protection system reacts to a drastic change in differential current of
IDN > 30 mA and disconnects the Sunny Boy from the grid within 0.2 sec.
Differential current
The fault "Drastic change in differential current" can only occur in transformerless inverters.
Transformerless inverters can be identified by their device designation. The "TL" in the name
stands for transformerless, e.g. Sunny Boy 10000TL‑US.