12 Parameters
SMA Solar Technology AG
102
SCCP-JP-BA-A4-en-12
User Manual
DtSet
Date
20060101 to
20991231
yyyymmdd
‒
ExlStrStpEna*
Activation of external shutdown signal/
remote shutdown
Off
Deactivated
Off
On
Activated
Activation of hermetic protection of MV
transformer
Off
Deactivated
On
On
Activated
ExtSolIrrOfs
Offset of the external irradiation sensor − 5,000 W/m
2
to 5,000 W/m
2
‒
0 W/m
2
ExtSolIrrGain
Amplification of external irradiation
sensor
− 1,000 W/m
2
to 1,000 W/m
2
‒
1
Grid monitoring time after grid error
0 s to 10,000 s ‒
300 s
GdChkTm*
Grid monitoring time after system start
0 s to 10,000 s ‒
300 s
MppFact
Ratio between maximum power P
MPP
of
the PV cell at the maximum power point
and the product of open-circuit voltage
V
OC
and short-circuit current I
SC
0.5 to 1
‒
0.8
Ofs_h-On***
Offset for operating hours
0 h to
2,147,482 h
‒
0
Offset for feed-in hours
0 h to
2,147,482 h
‒
0
Ofs_E-Total***
Offset for total supplied energy
0 kWh to
214,748,367
kWh
‒
0
Offset for operating hours of heat sink
fan
0 h to
2,147,482 h
‒
0
Ofs_CntFanCab1* Offset for operating hours of internal fan
1
0 h to
2,147,482 h
‒
0
Ofs_CntFanCab2* Offset for operating hours of internal fan
2
0 h to
2,147,482 h
‒
0
Ofs_CntHtCab1*
Offset for operating hours of internal
heating element 1
0 h to
2,147,482 h
‒
0
Ofs_CntHtCab2*
Offset for operating hours of internal
heating element 2
0 h to
2,147,482 h
‒
0
PvPwrMinTr
Threshold for starting the MPP tracker
0 kW to 20 kW ‒
20 kW
PvPwrMinTrT
Timeout for starting the MPP tracker
1 s to 1,800 s ‒
600 s
PvVtgStrLevMin*
Threshold for switching to feed-in
operation
0 V to 1,200 V SC 500CP-JP
410 V
0 V to 1,200 V SC 630CP-JP
610 V
0 V to 1,200 V SC 800CP-JP
760 V
Name
Description
Value/range Explanation
Default value