SMA Solar Technology AG
12 Parameters
User Manual
SCCP-JP-BA-A4-en-12
105
12.3 Sunny String
-
Monitor
Name
Description
Value/range
Explanation
Default
value
TMittelung*
Duration of measured current
value averaging
0 s to 6 000 s
‒
30 s
String number*
Number of detected PV strings
0 to 8
‒
0
SW version
Current firmware version
1 to 40
Value cannot be
changed
SSM Identifier*
Identification number of
Sunny String-Monitor
1 to 99
‒
0
Group String
Assigns PV strings to their
respective group
0 to 3
Parameter exists for all
eight groups
0
All groups
0 to 3
‒
0
No.of String
Number of connected strings in
the respective group
1 to 4
Parameter exists for all
eight groups
Contact the SMA Service
Line if you wish to use this
function.
−
All groups
1 to 4
‒
−
Monitoring
1
Start of monitoring of PV strings
in group 1
0:00 a.m. to
11:59 p.m.
Parameter exists for all
eight groups
Configuration of the
string settings via the
Sunny Central
String-Monitor Controller
is preferable.
0
Monitoring
1
Off*
End of monitoring of PV strings in
group 1
0:00 a.m. to
11:59 p.m.
Parameter exists for all
eight groups
Configuration of the
string settings via the
Sunny Central
String-Monitor Controller
is preferable.
0
Monitoring On*
Start of monitoring of PV strings
in all groups
0:00 a.m. to
11:59 p.m.
‒
0
Monitoring Off*
End of monitoring of PV strings in
all groups
0:00 a.m. to
11:59 p.m.
‒
0