Operation of the Sunny Central String-Monitor
SMA Solar Technology AG
66
SSMUS-TUS094511
Technical Description
11.4.1 Parameters for Sunny Central String-Monitor Controller
The following table lists the parameters displayed in the user and installer modes. The parameters with
a grey background are only visible in the installer mode.
Name
Adjustment range Default setting
Description
Ackn
quit
Confirm errors and warnings
manually.
Confirmation of a warning or error
which has occurred in the Sunny
Central String-Monitor or the Sunny
Central String-Monitor Controller.
ComBaud
–––, 1200Baud,
4800Baud,
9600Baud,
19200Baud,
38400Baud,
57600Baud
19200
Speed of data transfer via the
communication bus.
DevFunc
–––,
AutoDetect_SSMU,
DetectSSMURetry,
DelAll_SSMU,
Factory
AutoDetect_SSMU: Deletion of all
detected and registered Sunny
Central String-Monitors and
subsequent search for the Sunny
Central String-Monitors.
DetectSSMURetry: Continue search
for further Sunny Central String-
Monitors which have so far
remained undetected.
DelAll_SSMU: Deletion of all Sunny
Central String-Monitors registered in
the Sunny Central String-Monitor
Controller.
Factory: Set all the parameters
visible in the installer mode back to
default settings.
Dt
yymmdd
Current date of the Sunny Central
String-Monitor Controller.
yy: year, mm: month, dd: day
E.g., for July 4, 2009, enter
"
070409
".