No.
Name
Description
Value
Explanation
Default
Value
262.04
PVResSOC
Width of the range
for the maintenance
of the battery state
of charge (%) of the
nominal capacity
(expert mode)
4% to 20%
–
✓
✖ 5 %
262.05
MinSlfCsm-
pSOC
Minimum width of
the self-consumption
range on the short-
est day of the year
as a percentage of
the battery capacity
(expert mode)
0% to 91%
Lithium-ion battery
✓
✖ 70 %*
Lead-acid battery
✓
✖ 35 %**
* The setting of the parameter
262.05 MinSlfCsmpSOC
to 70% for lithium-ion batteries corresponds to a discharge of 30% until the
SOC is reached (see
120.01 BatSoc
).
** The setting of the parameter
262.05 MinSlfCsmpSOC
to 35% for lead-acid batteries corresponds to a discharge of 65% until the SOC
is reached (see
120.01 BatSoc
).
13.2.2.7 Authent (270#)
No.
Name
Description
270.01
Auth.Code
Entry of the SMA Grid Guard code
✓
✖
13.2.3 Information (300#)
13.2.3.1 Inverter (310#)
311# Total
No.
Name
Description
311.01
EgyCntIn
Energy consumed by the Sunny Island inverter in kWh
✓
✓
311.02
EgyCntOut
Energy supplied by the Sunny Island inverter in kWh
✓
✓
311.03
EgyCntTm
Energy metering run time in hours
✓
✓
312# Device
No.
Name
Description
Value
(Plain text no.)
Explanation
312.01
Adr
Device address
Master (1)
Address
✓
✓
Slave1 (2)
Address
Slave2 (3)
Address
13 Parameters in Sunny Remote Control
SMA Solar Technology AG
Operating Manual
149
SI30M-44M-60H-80H-BE-en-33