No.
Name
Description
Value
(Plain text no.)
Explanation
312.03
ApplSel
Operating mode of the
Sunny Island (expert mode)
Offgrid
Sunny Island is operating in the
stand-alone grid.
✓
✓
OnGrid
Sunny Island is connected to
the utility grid.
312.05
SysFncSel
Selection of the on-grid sys-
tem (expert mode)
SelfConsOnly
Increased self-consumption
only
✓
✖
BackupOnly
Battery backup only
SelfConsBackup
Battery backup with increased
self-consumption
312.06
FwVer
Firmware version of the cen-
tral processing unit of the
master
–
–
✓
✓
312.07
SN
Serial number of the master
–
–
✓
✓
312.08
OnTmh
Operating hours
–
–
✓
✓
312.09
ClstCfgAt
Set configuration of cluster
1Phase1
Single-phase, one Sunny Island ✓
✓
1Phase2
Single-phase, two Sunny Island
inverters
1Phase3
Single-phase, three Sunny Is-
land inverters
3Phase
Three-phase, three Sunny Is-
land inverters
312.10
OpStt
Operating state of the Sun-
ny Island inverter
Operating (1)
Operation
✓
✓
Warning (2)
Warning
Failure (3)
Error
312.11
CardStt
SD memory card status mes-
sage
Off (1)
No SD memory card inserted
✓
✓
Operational (2)
Ready for operation
Mount (3)
Initialization
OutOfSpace (4)
No storage space available
BadFileSys (5)
No file system detected
Incomp (6)
File system incompatible
Parameter (7)
Parameter set write access
ParamFailed (8)
Parameter set write access
failed
WriteLogData (9) Log data write access
13 Parameters in Sunny Remote Control
SMA Solar Technology AG
Operating Manual
SI30M-44M-60H-80H-BE-en-33
150