3.2
Control Panel of the Sunny Island Inverter
=
A
B
D
E
F
H
G
C
Figure 2: Layout of the control panel
Position
Symbol
Designation
Status
Explanation
A
Start-stop button
TSS
−
By pressing the start-stop button, you can start or
stop the system. In display messages on the Sun-
ny Remote Control, the start-stop button is re-
ferred to as
TSS
.
B
"On" button
−
Pressing the "On" button will switch the Sunny Is-
land on. The Sunny Island is in standby mode af-
ter being switched on.
C
"Off" button
−
Pressing the "Off" button will switch off the Sun-
ny Island.
D
Inverter LED
Not glowing
The Sunny Island is switched off.
Glowing green
The Sunny Island is in operation.
Glowing orange
The Sunny Island is in standby mode.
Glowing red
The Sunny Island switched off due to an error.
Flashing quickly*
The Sunny Island is not configured.
Flashing slowly** The Sunny Island is in overnight shutdown.
E
Grid LED
Not glowing
There is no voltage present from the generator or
the utility grid.
Glowing green
Generator or utility grid is connected.
Glowing orange
The Sunny Island is synchronizing the stand-
alone grid with the generator or the utility grid.
Glowing red
Error at the connection of the generator or the
utility grid.
F
Battery LED
Glowing green
The state of charge is more than 50%.
Glowing orange
The state of charge is between 50% and 20%.
Glowing red
The state of charge is less than 20%.