SMA America, LLC
19 Parameter Lists
Technical description
SI4548_6048-US-TB_en-13
171
19.2.3 External Settings (230#)
231# Ext General
232# Grid Control
No. Name
Description
Value
Explanation
Default
value
01
PvFeedTmStr
Start feed-in
operation
04:00:00
02
PvFeedTmStp
Stop feed-in
operation
22:00:00
03
ExtLkTm
Lock time after
reverse power or
relay protection
0 min to 60 min
20 min
05
ExtSrc
Generator and
grid operating
mode
PvOnly
PV only
PvOnly
Gen
Generator
Grid
Grid
GenGrid
Generator/Grid
12
ChpEna
Combined heat
and power plant
Disable
Deactivated
Disable
Enable
Activated
No. Name
Description
Value
Explanation
Default
value
01
GdVtgMin
Minimum line
voltage
105.6 V
02
GdVtgMax
Maximum line
voltage
132 V
03
GdCurNom
Nominal grid
current
30 A
04
GdFrqNom
Nominal grid
frequency
60 Hz
05
GdFrqMin
Minimum power
frequency
59.3 Hz
06
GdFrqMax
Maximum grid
frequency
60.5 Hz