SMA
Technologie AG
Parameter Lists
Technical Description
SI5048-11:EE4206
Page 141
18.4 Functions in Operation
#410 Operation Inverter
#420 Operation Battery
Menu
no.
Para-
meter
no.
Parameter name
Range/
Short
descr.
Default
value
Description
#410
01
InvRs
(Stby)
Restart
---
triggers inverter reset
#410
02
ParaSto
Set1
Set2
---
Saves parameter settings:
= file 1
= file 2
#410
03
InvTmOpEna
Disable
Enable
Disable
activates time-controlled inverter
operation
#410
04
InvTmOpStrDt
yyyymmdd
20060101 start date of time-controlled inverter
operation
#410
05
InvTmOpStrTm
hhmmss
0
start time of time-controlled inverter
operation
#410
06
InvTmOpRnDur
hhmmss
0
run time for time-controlled inverter
operation
#410
07
InvTmOpCyc
Single
Daily
Weekly
Single
repeated cycle time for timer 1
#410
08
ParaLod
(Stby)
Set1
Set2
Factory
---
Loads parameter settings:
= file 1
= file 2
= factory settings
#410
09
CntRs
Inv
Bat
Gn
Gd
All
---
clears selected energy meter
Menu
no.
Para-
meter
no.
Name
Range/
Short
descr.
Default
Description
#420
01
ManChrgSel
Idle
Start
Stop
Idle
triggers equalization charge
(manual)
Summary of Contents for Sunny Island 5048
Page 22: ...The Sunny Island 5048 SMA Technologie AG Page 22 SI5048 11 EE4206 Technical Description...
Page 26: ...Safety Instructions SMA Technologie AG Page 26 SI5048 11 EE4206 Technical Description...
Page 94: ...Battery Management SMA Technologie AG Page 94 SI5048 11 EE4206 Technical Description...
Page 114: ...Connecting External Sources SMA Technologie AG Page 114 SI5048 11 EE4206 Technical Description...
Page 160: ...Contact SMA Technologie AG Page 160 SI5048 11 EE4206 Technical Description...
Page 169: ...SMA Technologie AG Glossary Technical Description SI5048 11 EE4206 Seite 169...
Page 171: ......