4 Operating the Off-Grid Inverter with Sunny Remote Control
SMA Solar Technology AG
34
SI80H-BE-BEN120810
Operating Manual
4.4.5 Selecting Menus and Parameters
Always select menus and parameters as described below.
1. Switch to installer mode (see Section 4.4.1).
2. Turn the button to the right until the return icon appears to the right of the required menu.
The Sunny Remote Control scrolls through the menu items on the display line by line.
3. Press the button. This accesses the subordinate menu level.
☑ The Sunny Remote Control shows the subordinate menu level. The selected menu level is
shown in the first line.
4. Repeat steps 2 and 3 until the Sunny Remote Control displays the first parameter page.
5. Turn the button to the right until the Sunny Remote Control displays the desired parameter.
6. To exit the parameter page and go to the superordinate level or the standard mode:
• Turn the button to the left until the return icon appears in the first line.
• To switch to a higher menu level, turn the button to the left until
<back>
appears.
• To switch to standard mode, turn the button to the left until
<home>
appears.
• Press the button.
Hint:
<back>
and
<home>
also appear at the end of the list if the button is turned to the right.