Sunny Island
Installation & Operating Instructions
BWRI33-12:EE
- 68 -
SMA Regelsysteme GmbH
6.3 Configuration after Restart (“Restart”)
If the Sunny Island has already been fully adjusted to an island grid it does not need
to be reconfigured after a restart. All settings are maintained even if the inverter is
switched off.
If you still want to change parameters to optimize the system please follow the in-
structions below:
When you reach the “INIT“ (0-0) menu after switching on the DC fuse of the Sunny
Island – as described in chapter 5 – confirm the automatic selection of “Restart“ by
pressing [ ENTER ] . This will not change any of the settings already made.
You will thus reach the menu branch selection “SETUP“ (0-3) where – as described
in chapter 7.4 – you can change the desired parameters in the corresponding
“PARxxx“ (3+3 ... 3+9) menus after entering the installer password in the “PASSWD”
(3-2) menu.
If you have not pressed [ ENTER ] early enough you will reach the menu branch se-
lection “DATA“ (0-1). From here it is also possible to reach all menus with the in-
staller password and change the parameters there.
Changes of parameters should always be made in standby mode.
Otherwise the corresponding operating values will change immedi-
ately after pressing [ ENTER ]. Then incorrect entries cannot be
changed fast enough and may lead to damages in the plant!