16 Technical Data
SMA Solar Technology AG
Operating Manual
STPx0-3SE-40-BE-en-10
126
Maximal output overcurrent protection
32 A
All-pole sensitive residual-current monitoring unit
Available
Overvoltage protection
DC Type II / AC Type II
Active anti-islanding method
Frequency shift
General Data
Width x height x depth
500 mm x 598 mm x 173 mm
Weight
30 kg
Length x width x height of the packaging
595 mm x 795 mm x 250 mm
Weight including packaging
37 kg
Climatic category in accordance with
IEC 60721-3-4
4K26
Environmental category
Outdoors
Pollution degree outside the inverter
3
Pollution degree inside the inverter
2
Operating temperature range
-25°C to +60°C
Max. permissible value for relative humidity
(condensing)
100 %
Maximum operating altitude above MSL
3000 m
Noise emission, typical
30 dB(A)
Self-consumption (at night)
44 W
Power control / Demand response (DRED)
Communication via Modbus interface
Export limiting in accordance with AS/
NZS 4777.2
EMETER-20, HM-20
Demand response mode in accordance with
AS/NZS 4777.2
DRM0
Topology
Transformerless (Non-isolated)
Cooling method
Convection
Degree of protection in accordance with
IEC 60529 with mounted Wi-Fi antenna
IP65
Protection class in accordance with IEC 62103
I
Radio technology
WLAN 802.11 b/g/n
Radio spectrum
2.4 GHz
Maximum transmission power
100 mW
Summary of Contents for SUNNY TRIPOWER 10.0 SMART ENERGY
Page 132: ...www SMA Solar com...