7 Electrical Connection
SMA Solar Technology AG
Operating Manual
STPx0-3SE-40-BE-en-10
48
1 3 5 7 9
1 3 5 7 9
2 4 6 8 10 12 14 16 18
2 4 6 8 10 12 14 16 18
BMS/CAN
DI
DO
11 13 15 17
11 13 15 17
Figure 14: PIN overview
Pin
Pin assignment
BMS/CAN
1
CAN H
2
Enable signal
3
CAN L
4
Enable ground
5
Not assigned
6
Shielding
DI
7
Not assigned
8
Shielding
9
DI2
10
DI1
11
DI4
12
DI3
13
Fast stop
14
12 V
15
Not assigned
16
Not assigned
DO
17
NO (Normally Open)
18
COM
Summary of Contents for SUNNY TRIPOWER 10.0 SMART ENERGY